SYNTHETIC RECORD, NOT A REAL MEDICAL RECORD — Progress Note 7 — Focused Visit (Care-plan review) — George Washington — True-date frame: synthetic events are moved into the patient's historical lifetime. Codes, instruments, and treatments remain modern and are anachronistic.

PatientGeorge Washington
Date of birth1732-02-22
IdentifiersMRN HR-EN006-SYN-TD; SSN (made up) 000-06-1942
Document date1790-07-13
AuthorEleanor Pritchard-Boateng, MD
CustodianSt. Posthumous Health Center

Readable copy of the C-CDA narrative, generated with the XML. Coded entries are in the XML file beside this page.

Chief Complaint

Six-month review with the implant-retained lower overdenture. [S]

History of Present Illness

Mr. Washington returns six months after intake. Three weeks ago the prosthodontist connected stud attachments to the two implants and picked them up into the lower denture, which now clicks into place; he saw the prosthodontist again four days later for a planned check, and no adjustment was needed. He rates his chewing 8 out of 10 and eats a full diet, including meat and raw fruit; he stopped the nutritional supplement two weeks ago. He has given several speeches without the lower denture moving and no longer worries about it at dinners. He cleans the dentures and the attachments daily and keeps the dentures out overnight. His cough has gone and he is back to full days. His weight is 94.8 kg. [S]

ElementDetail
OverdentureAttachments connected three weeks ago; check at four days without adjustment
Chewing8 of 10; full diet
SpeechSpeeches given without the denture moving
Weight94.8 kg, up 2.4 kg from intake
Nutrition screenMNA-SF 12 of 14; albumin 4.1 g/dL

Review of Systems

SystemResultFinding
ConstitutionalNegativeEnergy back to normal
Ears, nose, mouth, and throatNegativeNo sore spots or bleeding around the implants
RespiratoryNegativeCough gone
GastrointestinalNegativeEating a full diet without difficulty

4 systems reviewed. [S]

Medications

MedicationFrequencyRouteDatesStatusEvidence
Acetaminophen 500 mg oral tablet, one or two tablets every six hours as needed for mouth pain, no more than six tablets (3 g) a dayOne or two tablets every six hours as needed; no more than six a dayOral route1790-01-19activeS
Amoxicillin 500 mg oral capsule, two capsules (1 g) three times daily for five days, for community-acquired pneumoniaTwo capsules three times daily for five daysOral route1790-05-11 to 1790-05-15completedS
Amoxicillin 500 mg oral capsule, four capsules (2 g) once, one hour before implant surgeryFour capsules once, one hour before surgeryOral route1790-03-23 to 1790-03-23completedS
Chlorhexidine gluconate 0.12% oral rinse, 15 mL rinsed for 30 seconds and spat out twice daily for two weeks after implant surgeryRinse 15 mL for 30 seconds twice daily for two weeks; do not swallowOral route1790-03-23 to 1790-04-06completedS
Ibuprofen 400 mg oral tablet, one tablet with food every six to eight hours as needed for up to three days after implant surgeryOne tablet with food every six to eight hours as needed for up to three daysOral route1790-03-23 to 1790-03-26completedS

Allergies and Intolerances

AllergyReactionStatusEvidence
No known allergyactiveS

Vital Signs

DateMeasureValueUnitProvenance
1790-07-13Body height188cmS
1790-07-13Body weight94.8kgS
1790-07-13Body mass index (BMI) [Ratio]26.8kg/m2S
1790-07-13Systolic blood pressure122mm[Hg]S
1790-07-13Diastolic blood pressure76mm[Hg]S
1790-07-13Heart rate66/minS
1790-07-13Respiratory rate14/minS
1790-07-13Body temperature36.6CelS
1790-07-13Oxygen saturation in Arterial blood by Pulse oximetry98%S

Results

DateMeasureValueUnitReference rangeFlagProvenance
1790-07-13Albumin [Mass/volume] in Serum or Plasma4.1g/dL3.5-5 g/dLNormalS

Physical Exam

Vital signs recorded on 1790-07-13; see the Vital Signs section. [S]

SystemFinding
GeneralWell; weight 94.8 kg, BMI 26.8; blood pressure 122/76, pulse 66
MouthPeri-implant mucosa pink without bleeding or swelling; attachments clean; no ulcer, red or white patch on the lips, cheeks, tongue, floor of mouth or palate
DenturesUpper denture stable; lower overdenture firmly retained on both attachments and stable on wide opening; even occlusion; lower lip support improved
RespiratoryClear

Problems

ProblemClinical statusVerificationCodeProvenance
Pain and difficulty chewing and speaking with loose, worn complete dentures that click and move; cause and treatment under evaluation with prosthodonticsresolvedconfirmed K08.9S — Synthetic presenting problem anchored to his documented painful dentures; superseded when the consultation made the diagnosis.
Complete edentulism of both jaws (American College of Prosthodontists diagnostic index class III: mandibular bone height about 14 mm, a flat lower ridge, a high muscle attachment), with complete dentures more than eight years old that no longer fit; synthetic modern diagnosis linked to his documented tooth loss from his twenties and his full denturesactiveconfirmed K08.103S — Synthetic modern diagnosis made at the prosthodontic consultation; the cause is recorded as unspecified because the sources do not establish why his teeth were lost.
Two shallow ulcers under the lower denture flange, probably traumatic from an ill-fitting denture, with no induration, red or white patch, or neck lymph node; to be re-examined two weeks after the denture is left out between mealsresolvedconfirmed K12.1S — Synthetic oral finding at intake; healed by the consultation, which confirmed denture-related traumatic ulcers.
Unintended weight loss of about 5.6 kg (6%) over six months from a narrowed, soft diet; at risk of malnutrition (MNA-SF 10)resolvedconfirmed R63.4S — Synthetic nutrition problem linked to the documented difficulty eating with dentures.
Community-acquired pneumonia of the right lower lobe, CURB-65 0, treated as an outpatient; seven weeks after lower implants were placed; resolvedresolvedconfirmed J18.9S — Synthetic acute illness echoing, in much milder form, his documented pneumonia of May 1790; not a claim about its cause.

Assessment and Plan

Protocol monitoring: items the monitoring protocol calls for at this visit. [S]

DomainMeasureIntervalStatusDetail
ExaminationOral mucosal examination and oral cancer screening (lips, cheeks, tongue, floor of mouth, palate, ridges, neck nodes)Every visitCompleted todayNormal
ExaminationDenture fit: retention, stability, occlusion, vertical dimension and sore spotsAt diagnosis, 24 hours to one week after delivery, after each adjustment, then yearlyCompleted todayPlanned check four days after attachment pick-up kept, no adjustment needed; today firm retention, stable, even occlusion
ExaminationImplant sites and peri-implant mucosaOne to two weeks after surgery, at attachment connection, then at each review and yearlyCompleted todayPeri-implant mucosa healthy without bleeding; attachments clean
ImagingRadiographs of the implantsAt the first yearly recall, then as indicatedDueAt the first prosthodontic recall
ExaminationWeightEvery visitCompleted today94.8 kg, up 2.4 kg from intake
SurveyNutrition screen (MNA-SF, recorded as narrative)At baseline when at risk, after about three months, and at six monthsCompleted todayMNA-SF 12 of 14 (normal): food intake 2, weight loss 3, mobility 2, recent illness 0 (pneumonia), neuropsychological 2, BMI 3
LaboratoryAlbuminAt baseline and at six months when at nutritional riskCompleted today4.1 g/dL, from 3.7 at intake
SurveyChewing and speech (patient-rated chewing ability out of 10; clarity of speech in reading aloud)Every visitCompleted todayChewing 8 of 10; speeches without the denture moving
Self-managementDenture hygiene: daily cleaning, dentures out overnight, ridge and tongue cleaning; attachment cleaningEvery visitCompleted todayDaily cleaning of dentures and attachments; out overnight
ReferralProsthodontic recallYearlyDueFirst recall in one year

Goal progress:

Immunizations given today: Recombinant zoster vaccine, second of two doses [S]

Guideline basis: Evidence-based guidelines for the care and maintenance of complete dentures: a publication of the American College of Prosthodontists (2011); The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients (2002); The York consensus statement on implant-supported overdentures (2009); Evidence-based clinical practice guideline for the evaluation of potentially malignant disorders in the oral cavity: A report of the American Dental Association (2017); Validation of the Mini Nutritional Assessment short-form (MNA-SF): a practical tool for identification of nutritional status (2009); Adult Immunization Schedule by Age (2026)

Follow-up: Second recombinant zoster dose given today. Prosthodontic recall in one year. Preventive visit in eight months. [S]