SYNTHETIC RECORD, NOT A REAL MEDICAL RECORD — Otolaryngology Consultation — Ludwig van Beethoven

PatientLudwig van Beethoven
Date of birth1995-12-16
IdentifiersMRN HR-EN010-SYN; SSN (made up) 000-10-5824
Document date2026-04-27
AuthorInes Albrecht, MD
CustodianSt. Posthumous Health Center

Readable copy of the C-CDA narrative, generated with the XML. Coded entries are in the XML file beside this page.

Reason for Referral

Progressive hearing loss in both ears over about three years, worse on the left, with constant bilateral tinnitus and intolerance of loud sound, in a 30-year-old professional pianist and composer. Please characterize the loss, look for treatable or retrocochlear causes, and advise on hearing rehabilitation suited to a musician and on managing the tinnitus. [S]

Urgency: Routine, within two weeks, with a same-day comprehensive audiologic evaluation. [S]

Questions for the consultant:

History of Present Illness

Mr. van Beethoven, a 30-year-old pianist and composer, is seen at the request of Dr. Vandermeer for progressive hearing loss and tinnitus. He dates the decline to about three years ago, beginning in the left ear. He cannot follow soft speech or group conversation, hears the sounds but not the words of quiet speakers, and misses high notes at a distance. Constant ringing and buzzing in both ears keeps him awake. Loud sound is painful and distorted. He has had no sudden drops, vertigo, otalgia, otorrhea, ear surgery, head injury, or facial weakness, and takes no medicines. He has rehearsed and performed for many years without hearing protection. No family history of early hearing loss is known to him. He is afraid this will end his career as a performer and has kept it secret from colleagues. [S]

Historical basis. These claims are historical evidence, not findings from a modern examination.

6 later historical claims are omitted because they describe events after the index age. See the teaching note.

Allergies and Intolerances

AllergyReactionStatusEvidence
No known allergyactiveS

Problems

ProblemClinical statusVerificationCodeProvenance
Progressive hearing loss in both ears over about three years, worse on the left, with poor understanding of soft speech; type and cause not yet established at intake; audiology and otolaryngology evaluation requestedresolvedconfirmed H91.93S — Synthetic presenting concern anchored to his documented account; superseded by the diagnosis at the audiologic evaluation.
Persistent, bothersome tinnitus in both ears for about three years, constant ringing and buzzing day and night, with intolerance of loud sound; synthetic modern episode linked to his documented tinnitusactiveconfirmed H93.13S — Synthetic modern coding of the documented tinnitus.
Adjustment disorder with depressed mood in response to progressive hearing loss, with withdrawal from social gatherings; synthetic modern episode linked to his documented despair and isolationactiveconfirmed F43.21S — Synthetic modern diagnosis; the documented letters describe distress and withdrawal, and the record makes no claim about his real mental health.
Bilateral sensorineural hearing loss, asymmetric (left worse than right), sloping from normal or mild in the low frequencies to moderately severe in the high frequencies; no air-bone gap; synthetic modern episode linked to his documented progressive deafness, whose cause remains unknownactiveconfirmed H90.3S — Synthetic modern diagnosis made at the audiologic evaluation; it states no cause, because the retrospective theories are disputed.

Physical Exam

Vital signs recorded on 2026-04-27; see the referring visit's Vital Signs section. [S]

SystemFinding
EarsPinnae and canals normal; eardrums intact and mobile on pneumatic otoscopy; no middle-ear effusion
Tuning forks (512 Hz)Weber lateralizes to the right; Rinne positive on both sides
Nose and throatNormal
NeurologicalCranial nerves normal, including facial nerve function and corneal sensation; no spontaneous or gaze-evoked nystagmus; head impulse test normal; Romberg negative

Results

DateMeasureValueUnitReference rangeFlagProvenance
2026-04-27Hearing threshold Ear - right --250 Hz15dB25 dB HL or better is normal hearingNormalS
2026-04-27Hearing threshold Ear - left --250 Hz20dB25 dB HL or better is normal hearingNormalS
2026-04-27Hearing threshold Ear - right --500 Hz20dB25 dB HL or better is normal hearingNormalS
2026-04-27Hearing threshold Ear - left --500 Hz30dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - right --1000 Hz25dB25 dB HL or better is normal hearingNormalS
2026-04-27Hearing threshold Ear - left --1000 Hz40dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - right --2000 Hz40dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - left --2000 Hz55dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - right --3000 Hz50dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - left --3000 Hz65dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - right --4000 Hz55dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - left --4000 Hz70dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - right --8000 Hz60dB25 dB HL or better is normal hearingHighS
2026-04-27Hearing threshold Ear - left --8000 Hz75dB25 dB HL or better is normal hearingHighS
2026-04-27Patient Health Questionnaire 9 item (PHQ-9) total score [Reported]11{score}S
2026-04-27Total score [MDQ]2{score}S

Assessment

Data reviewed: Dr. Vandermeer's intake note. Intake results: hemoglobin 15.1 g/dL, TSH 1.8 mIU/L, HbA1c 5.2%, treponemal antibody nonreactive (index 0.12). Today's audiologic evaluation: pure-tone air and bone conduction with no air-bone gap; right ear 15, 20, 25, 40, 50, 55, and 60 dB HL and left ear 20, 30, 40, 55, 65, 70, and 75 dB HL at 250 to 8000 Hz; four-frequency averages 35 and 49 dB HL; speech reception thresholds 30 and 45 dB HL; word recognition 88% (right) and 64% (left) at comfortable levels; type A tympanograms; acoustic reflexes present at reduced sensation levels; distortion-product otoacoustic emissions absent above 1500 Hz on both sides; loudness discomfort levels reduced to 85 to 90 dB HL. Tinnitus Handicap Inventory 58. [S]

Plan of Treatment